7
Functions
Leica DISTO™ A6 1.0.0 gb
D
GB
F
I
E
P
NL
DK
S
N
FIN
J
CN
RC
ROK
PL
H
RUS
CZ
to be measured will flash in the display. Take the
necessary measurements. The result and the single
measurements appear on the display.
CAUTION: Right angle is necessary between the
second measurement and the resulting distance. We
recommend to press the DIST - key {A, 1} longer to
activate the perpendicular (min.) measuring function.
Indirect Measuring - Determination with three
points
See figure {L}
Press the PYTHAGORAS - key {A, 12} until the
correct symbol appears on the display. The length to
be measured appears flashing on the display. Take
the necessary measurements. The result and the
single measurements appear on the display.
CAUTION: Right angle is necessary between the
second measurement and the resulting distance. We
recommend to press the DIST - key {A, 1} longer to
activate the perpendicular (min.) measuring function.
Indirect Measuring - Determination of a parti-
al height with three points
See figure {M}
Press the PYTHAGORAS - key {A, 12} until the
correct symbol appears on the display. The length to
be measured appears flashing on the display. Take
the necessary measurements. The result and the
single measurements appear on the display.
CAUTION: Right angle is necessary between the third
measurement and the resulting distance. We recom-
mend to press the DIST - key {A, 1} longer to activate
the perpendicular (min.) measuring function.
Storage of Constants/Historical
Storage
Storage of a Constant
It is possible to store and recall a frequently used
value e.g. height of a room. Measure the desired
distance, press and hold STORAGE - key {A, 7} until
the device beeps to confirm the storage.
Recalling the constant
Press STORAGE - key {A, 7} to recall the constant
and make it available with a press on the EQUAL - key
{A, 5} for further calculations.
Special function: Adjusting the constant
A measured value can be adjusted. If you press the
EQUAL - key {A, 5}, the value starts blinking and can
be adjusted with the PLUS - key {A, 3} or MINUS -
key {A, 13}. Through pressing the EQUAL - key {A, 5}
again the adjustment is confirmed. Now the value can
be stored as usual as a constant.
Historical Storage
Press STORAGE - key {A, 7} twice quickly and the
previous 20 results (measurements or calculated
results) are shown in reverse order. Using the PLUS -
key {A, 3} and the MINUS - key {A, 13} allows to
navigate in the historical storage. Press EQUAL - key
{A, 5} to take a result from the historical storage to
use for further calculations.