65. Reading luminance values (Command: m u)
Readsluminancevalues.
Transmission
[m][u][][SetID][][FF][Cr]
Acknowledgement
[u][][SetID][][OK/NG][Data1][Data2][Data3][Data4][Data5][x]
Data100-64backlight0-100
Data200-ff:Upper2-byteofCA210measuredvalue
Data300-ff:Lower2-byteofCA210measuredvalue
CA210measuredvalueHex:0000-ffff,Decimal:0-
65535
Data400-ff:Upper2-byteofBLUmeasuredvalue
Data500-ff:Lower2-byteofBLUmeasuredvalue
Data600-ff:Upper2bytesofBLUNo.2sensor
measuredvalue
Data700-ff:Lower2bytesofBLUNo.2sensor
measuredvalue
BLUmeasuredvalueHex:0000-ffff,Decimal:0-65535
*CA210measuredvalueisenteredthroughthe
calibrationprocedureduringfinalassembly.Default
valueis0beforecalibration.
**Itmaynotbesupported,dependingonthemodel.
66. Status check (Command: s v)
Checkvariousstatuses.
Transmission
[s][v][][SetID][][Data][][FF][Cr]
Data 05:CheckthenormaloperationofNo.1and
No.2luminancesensors.
06:luminancesensorbeingused:
07:Checkthenormaloperationoftop,bottom,
ormaintemperaturesensors.
Acknowledgement
[v][][SetID][][OK/NG][Data][Data1][x]
WhentheDatais05
Data100:Allnormal
01:BLUsensor1normal,BLUsensor2fail
02:BLUsensor1fail,BLUsensor2normal
03:Allfail
WhentheDatais06
Data100:No.1luminancesensorisbeingused
01:No.2luminancesensorisbeingused
WhentheDatais07
Data100:Alltemperaturesensorsfail
01:Topnormal,Bottomfail,Mainfail
02:Topfail,Bottomnormal,Mainfail
03:Topnormal,Bottomnormal,Mainfail
04:Topfail,Bottomfail,Mainnormal
05:Topnormal,Bottomfail,Mainfail
06:Topfail,Bottomnormal,Mainfail
07:Alltemperaturesensorsnormal
WhentheDatais08
Acknowledgement
[v][][SetID][][OK/NG][Data][Data1][Data2][Data3][x]
Data1:Temperatureofthetopsensorareawhenthe
setispoweredoff.
Data2:Temperatureofthebottomsensorareawhen
thesetispoweredoff.
Data3:Temperatureofthemainsensorareawhen
thesetispoweredoff.
WhentheDatais09
Acknowledgement
[v][][SetID][][OK/NG][Data][Data1][Data2][x]
Data100-ff:Upper2-byteofFanSpeed
Data200-ff:Lower2-byteofFanSpeed
FanSpeed:Hex0-20D0,Decimal0-8400
**Itmaynotbesupported,dependingonthemodel.