7.2 FILTER MONITOR
Your thermostat can alert you that your system’s air filter
should be changed, by displaying
FILTER
in the time
temperature display area once the system’s fan has run
the number of hours specified by this setting’s limit. The
presence of the word
FILTER
on the screen will not effect
the operation of the thermostat. If equipped, the filter is
located in your heating/cooling equipment.
7.2.1 FILTER USAGE
To view the number of hours the thermostat has
activated the fan since the last timer reset:
Rotate the dial to the
AIR FILTER
position. The current
filter usage will be shown with
HRS FILTER
To reset the timer to 0. press
UP
or
DOWN
once.
Pressing
UP
or
DOWN
again will toggle between 0 and
the current value. The value in display when you exit this
mode will be the value retained in memory. Leave the
value at 0 to reset the timer.
To exit the
AIR FILTER
mode, rotate the dial to another
position.
7.2.2 FILTER LIMIT
This general rule will provide you with a good estimate of
your filter’s life in hours. Assume that the fan will run at
1/3 duty cycle or 8 hours per day. Common 90 day filters
are then good for 90*24/3=720 hours of use. This is the
default limit value. Setting the filter counter limit to 0000
will disable the change filter indicator. Valid entries are
from 0 to 2000hrs.
To set the number of hours of filter use before
replacement is indicated:
Rotate the dial to the
AIR FILTER
position. The current
filter usage will be shown with
HRS FILTER
Hold
NEXT
for 2 seconds. The Filter limit will be
displayed.
Refer to your Air Filter package to determine your
filters recommended life. If given in days, multiply by 8 to
find the recommended setting in hours of filter usage.
Use
UP/DOWN
keys to adjust the filter limit in 10 hour
increments to the recommended value.
Rotate the dial to
RUN
finish this setting.
7.3 ENERGY USAGE
Your thermostat records the total number of hours the
thermostat has activated heating and cooling with six
separate timers. They measure:
Today's cumulative heating time
Yesterdays cumulative heating time
Total cumulative heating time
Today's cumulative cooling time
Yesterdays cumulative cooling time
Total cumulative cooling time
To view
HEAT
or
COOL
energy usage:
Slide the mode switch to
HEAT
or
COOL
.
Rotate the dial to the
ENERGY USAGE
position, to
review today's usage.
HRS USAGE
,
Mode
and
Current
Day
are all shown along with the usage value.
Press
NEXT
to review yesterday's usage.
Press
NEXT
again to review Total usage. The Total
timer may be changed to zero by pressing
UP
or
DOWN
while Total time is displayed. To restore count, press
UP
or
DOWN
again.
To finish review and/or reset of this modes energy
monitor, rotate the dial to another mode, the current
values will be the values retained in memory. Leave the
value at 0 to reset the cumulative timer.
7.4 CALIBRATION OFFSET
Your thermostat is accurately calibrated at the factory to
within ±1°F An offset value up to ±5°F may be added to
the temperature value that the thermostat measures. This
may allow you to match this thermostat to another. To
change this offset from its default value of 0:
Open the door on the front of the thermostat.
Rotate the dial to
SET DAY/TIME
.
Simultaneously press
NEXT
and
HOLD
. The
Temperature Offset value will flash.
Use the
UP/DOWN
keys to adjust the offset value.
Return the dial to its
RUN
position to accept the new
value.
7.5 RESET
Your thermostat has two RESET buttons. The Software
RESET is on the front of the thermostat behind the door.
It is labeled
RESET
. HARDWARE RESET is on the rear of
the circuit board.
7.5.1 HARDWARE RESET
Use this small white button labeled
H_RST
after
changing Setup Option Jumper positions to effect the
changes. The Hardware RESET turns Heat, Air and Fan
off, resets the units' clock, and reads the Setup Option
jumper positions, before initiating normal operation.
7.5.2 SOFTWARE RESET
Use this feature to make all settings and programs their
default values The Software RESET button turns Heat, Air
and Fan off, resets the units' clock, and reads the Setup
7