Mustang Survival MD1250 Life Jacket User Manual


 
Testing the Automatic Inflator
NOTE: A left/right pair of fully armed MD1250 LPs and two MA7214-10
re-arm kits are required for this test.
1. Attach the LPs to the left and right sides (see Wearing the LP).
2. Enter water of an appropriate depth to keep the head above the
surface.
3. When submerged in water, the hydrostatic manual/automatic inflator
releases CO
2
into the inflation cell, inflating the LP.
4. Don the inflated LP (see Donning the LP).
5. Ensure the LPs float the user just slightly back of vertical in a relaxed
position with the mouth well above the surface of the water, and
experiment with different leg positions to become familiar with
changes in buoyancy and/or flotation characteristics.
6. Exit the water, remove the LPs, and completely deflate them – see
Deflating the LP.
7. Let the LPs dry thoroughly, then re-arm and repack them – see
Re-arming the LP, and Repacking the LP.
CAUTION: If in doubt about self inspection and servicing of the MD1250 LP
in accordance with these instructions, or of any test or inspection results,
take the LP to a Mustang Survival dealer for professional servicing.
CLEANING AND STORING THE LP
CAUTION: To avoid accidental auto-inflation when cleaning the MD1250 LP,
do not submerge it in water and do not spray liquid on the inflator.
NOTE: Do not dry clean the MD1250 LP.
1. Hand wash or sponge down the LP in warm, soapy fresh water.
2. Rinse the LP and inflator with clean fresh water, using a clean cloth.
3. Hang the LP to dry on a plastic coat hanger.
4. Store the LP in a warm, dry place out of direct sunlight.
Tactical Inflatable Side Pouch LP Owners Manual