4) Without twisting, fold the bladder over once and place into the
centre of the pouch between the two wings (Fig.9). Ensure the
yellow inflator pulltab is positioned so it hangs out from the bottom,
between the Velcro
TM
closure.
5) Position so that green indicator is visible through window.
6) Ensure yellow pulltab is still hanging out the bottom of the pouch.
7) Close Velcro
TM
at bottom of pouch.
IS YOUR PFD IN GOOD AND SERVICEABLE
CONDITION?
Check your Inflatable PFD between outings to be sure that it is properly
armed; that it is free of rips, tears or holes; that all seams are securely
sewn; and that the fabric, straps and hardware are still strong (See
Readiness Checklist, p. 2). Inspect the inflatable portion of the Inflatable
PFD in accordance with the CARE AND MAINTENANCE INSTRUCTIONS.
CARE AND MAINTENANCE INSTRUCTIONS
Federal Regulations require Coast Guard approved personal flotation
devices (PFDs) that are legibly marked with the Coast Guard approval
number, are in good and serviceable condition, and are the correct size
for each person on board. It is the responsibility of the operator to be
sure this PFD is in serviceable condition. To be considered serviceable,
this PFD shall not exhibit deterioration that could diminish its
performance, such as broken or deformed hardware, detached webbing,
rotted structural components, air leaks or nonfunctional inflators. Unless
worn inflated, this PFD must also be properly armed with a cylinder
installed in the inflator, and service indicator showing green. See Page 2
for instructions. Failure to follow these instructions rigorously could result
in a non-functioning PFD causing injury or death.
Check the following at the intervals listed below.
1) Before Each Use:
i) Examine the service indicator through the window panel,
ensuring it is green. If the indicator is red, the mechanism requires
service. See Re-arming Your PFD (MD3075), p.6.
9 Inflatable PFD Owner’s Manual