Mustang Survival MD3085 Life Jacket User Manual


 
Tab
Piercing Pin
Cylinder
Lever
Service Indicator
MD3085 Manual Inflator
1/8 Turn
Cylinder
1/8 Turn
Tab
Piercing Pin
Lever
Service
Indicator
MD3081 and MD3082 Manual Inflator
FIGURE 8
5) Examine the service indicator (Fig. 8) and ensure it is GREEN. If
the service indicator is red, the mechanism has been fired or is
incorrectly fitted and the inflator requires service. See Re-arming Your
PFD (MD3085) p. 8.
NOTE: The service indicator must be green before proceeding.
6) Refold the Inflatable PFD in accordance with the Repacking section
(p. 13).
YOUR INFLATABLE PFD (MD3085) IS NOW READY FOR MANUAL USE
Re-arming Your PFD (MD3087)
NOTE: A re-arm kit (MA7202) with a valid bobbin install-by-date
(check re-arm kit packaging) is required for this procedure.
IMPORTANT: Follow instructions in the exact sequence below.
1) Unpack or open the Inflatable PFD so that the manual/automatic
inflator is exposed (Fig. 9).
2) Remove the cylinder/bayonet assembly by rotating counter-clockwise
and then pull out. Discard the used cylinder/bayonet assembly.
NOTE: You will damage the sensor ring if bobbin and cap are
not installed first.
3) Remove cap by turning counter-clockwise. (Fig. 9).
4) Remove bobbin from cap or housing unit. Discard bobbin.
NOTE: The yellow bobbin may remain in the housing or in the
cap assembly when you remove the cap. The bobbin must be
Inflatable PFD Owner’s Manual 10 11 Inflatable PFD Owner’s Manual