Mustang Survival MD3085 Life Jacket User Manual


 
Re-arming Your PFD (MD3087) (p. 10).
NOTE: The service indicator must be green before proceeding.
12) Refold the Inflatable PFD in accordance with the Repacking section
(p. 13).
YOUR INFLATABLE PFD (MD3087) IS NOW READY FOR MANUAL USE
WITH AUTOMATIC BACKUP
Service
Indicator
Groove
Pull-cord
Tab
Piercing
Pin
Cylinder
MD3087 Automatic Inflator
1/8 Turn
FIGURE 11
Repacking
Gently squeeze the Inflatable PFD until all air or gas has been expelled
(Fig. 5). Do not wring or twist the Inflatable PFD. Put the inflation tube
dust cap back in its stowed position on the oral inflation tube (Fig. 6).
NOTE: Before following the repacking sequence, be sure to
properly re-arm your Inflatable PFD.
1)
Fold
side (A) inward along the full length of the dotted line (Fig. 13).
2) Fold lapel (B) inward along dotted lines. Fasten along the full length
of the Velcro™. Ensure that the Inflatable PFD is tucked under the
Velcro™ strip.
3) Repeat steps 1 and 2 with side (C) and lapel (D). Your Inflatable PFD
will look as illustrated in Fig. 14.
4) Fold down the collar (E) along the dotted line (Fig. 14).
5) Fold the cover (F) up over the collar and fasten with (3) Velcro™ tabs
(Fig. 14 inset).
6) Ensure the pull-tab is on the outside of the folded Inflatable PFD. Fig.
Inflatable PFD Owner’s Manual 12 13 Inflatable PFD Owner’s Manual