Nikon SB-800 Marine Instruments User Manual


 
79
Setting a group and channel number on the remote flash units
1
Press the g button on the remote flash unit to
highlight the channel number, then press the e
or f button to set the channel number.
Be sure to choose the same channel number as set
on the master flash unit.
2
Press the g button on the remote flash unit to
highlight the group, then press the e or f
button to set the group.
For remote flash units where the flash mode and
flash output level compensation values are to be
set identically, place these flash units into the
same group.
v Notes on using camera’s built-in flash in Commander mode
Camera Available flash mode of Usable channel Usable group
built-in flash number
D200, D80 TTL, M, -- (Flash canceled) 1 to 4 A, B
D70-Series (Flash canceled) 3 A
u Setting in the Repeating flash mode
When the master flash unit is set to the q (repeating flash) mode, set the flash output
level, the frequency (Hz) and the number of repeating flashes per frame. (Refer to
“Repeating q flash” on page 48.)
1
Press the g button to highlight the
flash output level display, then press the
e or f button to increase or decrease
the values.
2
Press the g button.
The flash output level is set, then the
frequency display is highlighted.
3
Repeat the procedures above to set the
frequency and the number of repeating
flashes per frame.
If Repeating flash has been set on the master flash unit, either the Repeating flash mode
or Flash canceled mode can be set on the remote flash units from the master unit.
Advanced operations
Number of repeating
flashes per frame
Flash output level
Frequency (Hz)