TROUBLE-SHOOTING AND STORAGE
Most treadmill problems can be solved by following the simple steps below. Find the symptom that applies,
and follow the steps listed. If further assistance is needed, call our Customer Service Department toll-free at 1-
800-999-3756, Monday through Friday, 6 a.m. until6 p.m. Mountain Time.
1. SYMPTOM: THE POWER DOES NOT TURN ON
a. Make sure that the power cord is plugged into a properly grounded outlet. (See PLUGGING IN THE
POWER CORD on page 7.) If an extension cord is needed, use onlya 14-gauge general-purpose cord of
five feet or less in length.
b. After the power cord has been plugged in, make sure that the safety key is fully inserted into the console.
Various indicatorson the console should light. (See OPERATION AND ADJUSTMENT on page 7.)
c. Check the circuitbreaker located on the treadmill near the
power cord. If the switch protrudes as shown, the circuit break-
er has tripped. To reset the circuit breaker, wait for five min-
utes and then press the switch back in.
d. Check the on/off switch located on the treadmill near the
power cord. The switch must be inthe ON position.
2. SYMPTOM: THE POWER TURNS OFF DURING USE
Tripped _ Reset
°"¢¢
a. Check the circuitbreaker located on the treadmill near the power cord. If the circuit breaker has tripped (see
the drawing above.), wait for five minutes and then press the switchback in.
b. Make sure that the power cord is plugged in.
c. Remove the safety key from the console. Reinsert the safety key fullyinto the console. Various indicators on
the console should light.
d. Check to make sure the on/oft switch is in the ON position. (See 1. d. above.)
e. Ifthe treadmill stillwill not run, please call our Customer Service Department.
10
3. SYMPTOM: THE WALKING BELT SLOWS WHEN WALKED ON
a. Apply silicone lubricant to the walking platform before use. Reapply lubricant after every 10 hours of use,
and whenever a decrease in performance is noticed. (Uni.Sport silicone spray is recommended.) CAU-
TION: UNPLUG THE POWER CORD WHEN APPLYING LUBRICANT. (See OPERATION AND ADJUST-
MENT on page 7 for application instructions.)
b. Ifan extensioncord is needed, use onlya 14-gauge generel-purpose cord of five feet or less in length.
C.
If the walking belt is overtightened, treadmill performance may
decrease and the walking belt may be permanently damaged.
Remove the safety key and UNPLUG THE POWER CORD.
Using the 3/16" allen wrench, turn both rear rolleradjustment
bolts counterclockwise, 1/4 of a turn. When the walking belt is
properly tightened, you should be able to lifteach side of the
walking belt 3-4 inches off the walking platform. The center of
the walking belt should just touch the walking platform. Be care-
ful to keep the walking belt centered. Plug in the power cord,
insert the safety key and run the treadmill for a few minutes.
Repeat untilthe walking belt is properlytightened.
I R_justment Bolts