TABLE 3.1. BATTERY POWER INDICATOR
Display Operation Figure 3.2
BAT + 4 segments + OK Normal, full battery. a
BAT + 3 segments Normal, battery power is getting low
or the temperature is low.
Battery replacement is recommended
if you are going to colder conditions or
if you are planning to make a dive trip.
b
LOWBAT + 2 segments
+ low battery symbol
Battery power is low and the battery
replacement is recommended. The
battery symbol is displayed.
c
LOWBAT + 1 segments
+ QUIT + low battery
symbol
Change the battery! Returns to
the Time display. Activation and all
functions are disabled.
d
Temperature or an internal oxidation of the battery affects the battery voltage. If the
instrument is stored for a long period, the low battery warning may be displayed even
though the battery has enough capacity. The low battery warning may also be dis-
played at low temperatures, even though the battery has enough capacity in warmer
conditions. In these cases repeat the battery check procedure.