Suunto SS021643000 Scuba Diving Equipment User Manual


 
To set the dive time alarm:
1. While in a relevant dive mode, keep [DOWN] pressed.
2.
Press [DOWN] or [UP] to scroll to ALARM TIME.
3. Press [UP] to toggle the alarm on and press [SELECT] to confirm.
4. Adjust the duration with [UP] or [DOWN] and accept with
[SELECT].
5. Press [MODE] to exit.
3.15 Error state (algorithm lock)
Suunto Zoop Novo has warning indicators that alert you to react to
certain situations that would significantly increase the risk of DCI. If
you do not respond to these warnings, Suunto Zoop Novo enters an
error state and shows Er on the display. This indicates that the risk
of DCI has greatly increased.
If you omit decompression stops for longer than three (3) minutes,
the RGBM algorithm is locked for 48 hours. When the algorithm is
locked, no algorithm information is available and ER is shown
instead. Locking the algorithm is a safety feature, highlighting that
the algorithm information is no longer valid.
40