SPECIFICATIONS
LP Internal
Regulator Conversion Reducer Inlet Wiring
Model Coil Gas Pipe Opening Regulator Adjustment Convertible Kit Line Flow Bushing Pressure Side See
Number Voltage Type Size Characteristic Setting Range Nat./LP Included Interrupter Direction Kit Tap Taps Figure
36C84-912 24 VAC Natural
3
/
4
x
3
/
4
Fast Open 3.5 2.5–5.0 Yes Yes No Str. Thru Yes Yes No 5
36C84-913 24 VAC Natural
3
/
4
x
3
/
4
Fast Open 3.5 2.5–5.0 Yes Yes No Str. Thru Yes Yes No 7
36C84-916 24 VAC Natural
3
/
4
x
3
/
4
Fast Open 3.5 2.5–5.0 No No No Str. Thru Yes No No 8
36C84-921 24 VAC Natural
3
/
4
x
3
/
4
Fast Open 3.5 2.5–5.0 Yes Yes No Str. Thru Yes Yes No 5
36C84-923 24 VAC Natural
3
/
4
x
3
/
4
Fast Open 3.5 2.5–5.0 No No No Str. Thru No Yes No 9
36C84-926 24 VAC Natural
3
/
4
x
3
/
4
Fast Open 3.5 2.5–5.0 No No No Str. Thru Yes No No 4
36C84-936 24 VAC LP
3
/
4
x
3
/
4
Fast Open 11.0 7.5–12.0 No No No Str. Thru Yes No No 4
36C87-944 24 VAC Natural
3
/
4
x
3
/
4
Step Open 1.0 1.0/3.5 2.5–5.0 No No No Str. Thru Yes No No 6
36C94-906 24 VAC Natural
3
/
4
x
3
/
4
Slow Open 3.5 2.5–5.0 No No No Str. Thru Yes No No 5
36C94-907 24 VAC Natural
3
/
4
x
3
/
4
Slow Open 3.5 2.5–5.0 Yes Yes No Str. Thru Yes No No 4
Wiring diagrams – see pages 3-6
Electrical Rating: 0.6 amps
End to End Dimensions: 3
15
/16
Ambient Operating Range: –40 to +175°F (–40 to 79°C)
Maximum Pressure Rating:
1
/2 PSI (14.0 W.C.)
Agency: A.G.A. and C.G.A. design certified
AGA STD. NAT GAS LP GAS AGA STD. NAT GAS LP GAS
Pipe Size 1000 BTU/CU. FT. 2500 BTU/CU. FT. 1000 BTU/CU. FT. 2500 BTU/CU. FT.
1/2 X 3/8 100,000 162,000 15,000-100,000 15,000-162,000
1/2 X 1/2 230,000 372,600 30,000-290,000 30,000-469,000
1/2 X 3/4 230,000 372,600 30,000-290,000 30,000-469,000
3/4 X 3/4 280,000 453,600 50,000-400,000 50,000-648,000
1" Pressure Drop Capacity Rated Range of Regulation
BTU/HR BTU/HR
www.white-rodgers.com
Outlet Pressure