Xantrex Technology 150 Marine Battery User Manual


 
13
Symptom The AC load runs for more than one minute,
the alarm sounds, and the light comes on. The
inverter is warm or hot to touch.
The AC load will not operate; no inverter lights are on.
Symptom The cigarette lighter works in the lighter
socket, but the inverter does not.
Symptom The cigarette lighter does not work in the
lighter socket.
Possible cause Suggested remedy
Poor ventilation or a high-
temperature environment has
caused the inverter to overheat.
Ensure that ventilation is not
restricted around the inverter.
Possible cause Suggested remedy
The contact between the plug
and the lighter socket or the 12
volt outlet is poor.
Press the plug firmly into the
socket. Clean the plug or the
socket if necessary.
The inverter has been connected
with reverse DC input polarity.
The inverter has probably been
damaged. Have it repaired.
Instructions for returning the
inverter are on page 22.
Damage caused by reverse
polarity is not covered by the
warranty.