INSTALLATION MANUAL • 22.
ERROR CODES
Error
Code
Error Call Out in Display Description of Error Possible Cause
E34
Steam Generator Drain
Water level in steam
generator does not drop
during cleaning program
drain pump.
water level probes.
— Generator drain pump is faulty.
— No output to pump from relay board.
E36
Oven cavity temperature is
a steam mode or cleaning
program
— Low water pressure.
— Wiring or connection issue.
— Water injection pipe obstructed.
— No output to solenoid valve form relay board.
E51
No Water In Boiler Water inside steam generator
level
— Low water pressure.
— Generator drain cap missing or loose.
— Generator drain pump is not sealing.
— Generator drain pump elbow leaking.
— Wiring or connection issue.
— No output to dual solenoid from relay board.
E53
Temperature
— See Motor Control Error Code list.
E54
Temperature
— See Motor Control Error Code list.
E55
Vent Not Open Browning valve does not open — Alignment issue between motor cam and vent
— Wiring or connection problem.
continued on next page