ERROR CODES
Error
Code
Error Call Out in Display Description of Error Possible Cause
E57
No Rinse Water During rinse no water

solenoid valve

— Low water pressure.




E93



between display board and
low voltage relay board

— Ribbon cable defective.
— Relay board, low voltage, connector defective.
— Display board connector defective.
E94

TO Display Board

between display board and
low voltage relay board

— Ribbon cable defective.
— Relay board, low voltage, connector defective.
— Display board connector defective.
E98






E99






E100
DB is not equal to RB

by DB.

failed.

— Ribbon cable defective.
— Relay board, low voltage, connector defective.
— Display board connector defective.
— Software may need to be updated again.
E101
DB is not equal to RB

by RB.

failed.

— Ribbon cable defective.
— Relay board, low voltage, connector defective.
— Display board connector defective.
— Software may need to be updated again.
CONTROL ERROR CODES