Electrical Specifications
Unless otherwise stated, the specifications hold under the following conditions:
The meter is located in the far-field of a source, the sensor head is pointed towards the source.
Ambient temperature: +23C3C
Relative air humidity: 25% to 75%
Sensor type: Electrical field (E)
Frequency range: 900MHz, 1800MHz, 2.7GHz, 3.5GHz and 8GHz
(measurements can be made, for reference purposes
only, using the entire range of 10MHz to 8GHz
Specified measurement range:
CW signal (f > 900MHz): 20mV/m to 108.0V/m
53A/m to 286.4mA/m
1W/m
2
to 30.93W/m
2
0W/cm
2
to 3.093mW/cm
2
Dynamic range: Typically 75dB
Absolute error at 1 V/m & 900 MHz: 1.0dB
Frequency response:
Sensor (with typical CAL factors): 1.0dB (50MHz to 1.9GHz)
2.4dB (1.9GHz to 8GHz)
Isotropy deviation: Typically 1.0dB (f>900MHz)
Overload limit: 10.61mW/cm
2
(200V/m)
Thermal response (0 to 50°): 0.5dB