Fluke 433/434
Getting Started
8
Measuring Modes, a Quick Overview
This section gives an overview of all measuring modes. The Analyzer’s screen information and use of function keys is
explained in more detail in the next two chapters.
SCOPE
SCOPE MODE. The following features are available:
Measuring Mode Screen Type Representation of Measuring Results Cursor/Zoom
Scope Waveform Waveform Oscilloscope display of voltage/current + numerical values. Yes / Yes
Scope Phasor Vector Diagram Voltage/current phase relation + numerical values No / No
MENU
MEASUREMENTS MENU. Measuring Functions accessible via the MENU key. The following features are available:
Measuring Mode Screen Type Representation of Measuring Results Cursor/Zoom
V/A/Hz Table Numerical values: voltage, current, frequency, crest factor. No / No
Trend Trend over time of values in the table. Yes / Yes
Dips & Swells Trend Trend over time with fast update rate: Voltage/current. Yes / Yes
Table Records events that violate limits: normal/detailed tables
available.
No / No
Harmonics Bar Graphs Voltage/current/power harmonics, interharmonics, THD, DC Yes/ No
Table Numerical values of a set of (inter)harmonics No / No
Power & Energy Table Numerical values: Active power/Apparent power/ Reactive
power /Power factor/Displacement power factor/
Voltage/Current/Energy usage, Energy meter output pulse count
No / No
Trend Trend over time of the values in the table Yes / Yes