![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/6/3a/63a32f25-3d56-4029-84bb-e2d4b720ee1a/63a32f25-3d56-4029-84bb-e2d4b720ee1a-bga.png)
Diaphragm Metering Pump MEMDOS E - ATE
BW 1 04 02 / 10
Lutz-Jesco GmbH
Improved changes are always reserved without notice.
4. Safety instructions
The following safety instructions refer to the ATE
servomotor. The instructions contained in the
enclosed operating instructions for the metering
pump also apply for the extended installation.
⇒ When working on the metering equipment,
observe the local safety rules.
⇒ Before working on the metering pump and the
ATE servomotor, disconnect the main power supply
and protect it against reconnection.
⇒ Adjustment works in the interior of the ATE drive
must be carried out carefully. Connections and
internal limit switches might be "alive".
⇒ Additional limit switches might be "alive" even
with the auxiliary voltage switched off.
⇒ After installation works at the ATE servomotor
or before startup remount the cover.
5. Wiring diagrams
6. Start-up
Switch on the main drive motor of the metering
pump. With an electrical interlocking system, only
then can the ATE drive be adjusted.
To check the direction of rotation send short control
pulses to the ATE servomotor.
If the direction of rotation is wrong, the supply lines
(terminals 2 and 3 in the case of direct controls) are
reversed.
The ATE servomotor must be moved to the final
positions in order to check the limit stop mechanism
of the integrated limit switches. When leaving the
factory, the angle of rotation is 270°. If required, the
angle of rotation and thus the maximum flow rate
can be restricted. To achieve this, the upper trigger
cam is shifted by the required value.
Wiring diagram KNG 2.60 / 2.120
Wiring diagram KNG 2.60 / 2.120 ST
0/2...10V DC
4V AC L1
N
1
2
3
4
CLOSEDOPEN
Actuation through sensors,
switches, controller contacts, etc.
N
3
1
2
18
19
20
x = Any switch position
1. Voltage input
0-10V at terminals 1 and 4
ON xx xxxx
OFF x x x x x x
12345678
2-10V at terminals 1 and 4
ON xx xxxx
OFF x x x x x x
12345678
2. Current input
0-20 mA at terminals 1 and 4
ON xx xxxx
OFF x x x x x x
12345678
4-20 mA et terminals 1 and 4
ON xx xxxx
OFF x x x x x x
12345678
3. Direction of rotation
ON x xxxxxx
OFFx xxxxxx
12345678
ON x xxxxxx
OFFx xxxxxx
12345678
4. Output voltage
0-10V at terminals 1 and 3
ON x x x
OFF x x x
12345678
2-10V at terminals 1 and 3
ON x x x
OFF x x x
12345678
270°-0°
0°- 270° (default setting)
Setting of coding switch KNG 2.60 / 2120 ST