7. Equipment Commands
7-4
August 2002 4200-A2-GB20-00
REPT ALM EQPT
The REPT ALM EQPT message reports current alarms from the NE.
Table 7-3. REPT ALM EQPT Message Parameters
almcde atag REPT ALM EQPT aid_eqpts:ntfcde,cond_eqpt,
srveff,[ocrdat],[ocrtm]: [conddescr];
almcde Alarm code. Identifies the severity of the alarm. Values are:
– *C: Critical alarm
– **: Major alarm
– *^: Minor alarm
– A^: Automatic message (typically reports a cleared alarm)
atag Automatic tag. Indicates the numerical sequence of reported messages.
aid_eqpts Access identifier for the equipment. Each AID format can be preceded
with AID=, but this is not required. Enter in the following format,
replacing lower-case parameters with the values given:
– LT-rack-shelf-slot: LT unit
– SHELF-rack-shelf: shelf
– rack: Rack Number (1)
– shelf: Shelf Number (1)
– slot: LT Slot Number (1)
[ntfncde] Notification code. Valid values are:
– CR: Critical alarm
– MJ: Major alarm
– MN: Minor alarm
– CL: Cleared alarm
cond_eqpt Equipment condition. Valid values are:
– EQPT: Equipment failed self-test
– FANALM-1: Fan alarm for fan 1
– FANALM-2: Fan alarm for fan 2
– PROGVER: Failed to load or find requested software
– RMTDLFAIL: Failed to download software
– SWROLLBACK: Software version rolled back
[serveff] Service effect. Valid values are:
– SA: Service affecting
– NSA: Not service affecting
[ocrdat] Date of alarm occurrence in the format mm-dd (month-day).
[ocrtm] Time of alarm occurrence in the format hh-mm (hour-minute).
[conddescr] Description of alarm condition (40 characters maximum).