![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/c/95/c95b2d9b-d09f-4cf1-9047-9ce8e7b5e42a/c95b2d9b-d09f-4cf1-9047-9ce8e7b5e42a-bg15e.png)
C. Traps and MIBs
C-26
August 2002 4200-A2-GB20-00
entPhysicalAlias
(entPhysicalEntry 14)
Identifies the alias name of the
physical entity as specified by the
network manager.
Read/write. Valid value is a zero-length string,
however the agent may set the value to a locally
unique default value.
entPhysicalAssetID
(entPhysicalEntry 15)
Identifies the user-assigned asset
tracking identifier of the physical
entity as assigned by the network
manager.
Read only. Valid values are the following:
Stack: zero-length string (read/write)
Chassis: zero-length string (read/write)
Main card: zero-length string (read/write)
Uplink module: zero-length string (read/write)
Splitter card: zero-length string (read/write)
ReachDSL port: zero-length string (read only)
T1/E1 port: zero-length string (read only)
Console port: zero-length string (read only)
Ethernet Mgmt port: zero-length string (read only)
Temp sensor: zero-length string (read only)
Fan: zero-length string (read only)
Management Plane PLD: zero-length string (read
only)
Led PLD: zero-length string (read only)
T1/E1 PLD: zero-length string (read only)
entPhysicalIsFRU
(entPhysicalEntry 16)
Identifies whether (TRUE) or not
(FALSE) this entity is considered
to be a field-replacable unit by the
vendor.
Read only. Valid values are the following:
Stack: TRUE
Chassis: TRUE
Main card: TRUE
Uplink module: TRUE
Splitter card: TRUE
ReachDSL port: FALSE
T1/E1 port: FALSE
Console port: FALSE
Ethernet Mgmt port: FALSE
Temp sensor: FALSE
Fan: FALSE
Management Plane PLD: FALSE
Led PLD: FALSE
T1/E1 PLD: FALSE
Table C-11. Entity Physical Group Objects (7 of 7)
Object Description Setting/Contents