Recall Timer
Code:
#107
Duration
Description:
Changes the length of the timed signal (a switchhook flash) exe-
cuted by the Recall feature (p. 4-8) and by the Recall function of speed dialing
(p. 3-36). Recall sends this timed signal over the phone line to the local tele-
phone company or PBX/Centrex to which the system is connected. Typically
you use the Recall feature to access PBX or Centrex features such as Call
Waiting.
Change the factory setting of the recall timer only under three conditions:
■
If your PARTNER Plus system is connected to Centrex, set the recall timer to
800 milliseconds (msec) by entering [ 3 ] [ 2 ].
■
If your PARTNER Plus system is connected to a PBX or Centrex and Recall
drops calls, shorten the time.
■ If pressing Recall has no effect, lengthen the time.
Valid Entries:
01 through 80 (25 to 2000 msec in 25 msec increments)
✓
18 (450 msec)
Programming Steps:
1. Press [ Feature ] [ 0 ] [ 0 ] [ System Program ] [ System Program ] [ # ] [ 1 ] [ 0 ] [ 7 ]
.
The
display reads:
Recall Timer
18 450-msec
2. Enter a different recall timer setting by pressing [ Next Data ] or [ Prev Data ]. For
example, to shorten the recaIl timer to 400 msec, press [ Prev Data ] twice.
The display reads:
Recall Timer
16 400-msec
Or enter the setting number directly. For example, to set the recall timer to 800
msec, press
[ 3 ] [ 2 ].
3. If you are using Recall to access PBX or Centrex features, test the new
Recall Timer Duration by trying to use these features:
■
If the call is disconnected, shorten the time.
■
If the Recall signal has no effect, lengthen the time.
✓
=
Factory Setting
To go to the next procedure: [ Next Proc
]
To go to a specific procedure: [ # ] [ x ] [ x ] [ x ] [ x ]
To go to the previous procedure: [ Prev Proc ]
(where XX X is the procedure number)
To return data to the factory setting: [ Remove ]
To exit system programming: [ Feature ] [ 0 ] [ 0 ]
System Programming 3-7