Hold Disconnect Code: #203
Time
Description:
When a caller on hold hangs up, the local telephone company
may send a special signal to the PARTNER Plus system to free the line. There
are two possible signals: a long signal (450 milliseconds) used by most tele-
phone companies, or a short signal (50 milliseconds) used by a few telephone
companies. The length of the signal is called the hold disconnect time. If you
put a line on hold and the call doesn’t “go away” within a minute or two after the
caller hangs up, use this procedure to change the hold disconnect time.
If the telephone company sends no signal, changing the hold disconnect time
has no effect. In this situation, disconnect held calls manually by taking the call
off hold and hanging it up.
Valid Entries:
✓
1
= Long (450 msec)
2 = Short (50 msec)
Programming Steps:
1. Press [ Feature ] [ 0 ] [ 0 ] [ System Program ] [ System Program ] [ # ] [ 2 ] [ 0 ] [ 3 ] . The
display reads:
HoldDisconnct
Line:
2. Enter the first line to be programmed. For example, to program line 2,
press [ 2 ] . The display reads:
HoldDisconnct L2
1 Long
3. To change the disconnect time, press [ Next Data ] . The display reads:
HoldDisconnct L2
2 Short
To program another line, press [ Next Item ] or [ Prev Item ] until the correct line number shows
on the display. Follow step 3 to change the disconnect time. Repeat for each line in the
system.
✓ = Factory Setting
To go to the next procedure: [ Need Proc ]
To go to a specific procedure: [ # ] [ x ] [ x ] [ x ]
To go to the previous procedure: [ Prev Proc
]
(where XXX is the procedure number)
To return data to the factory setting: [ Remove
]
To exit system programming: [ Feature ] [ 0 ] [ 0 ]