Becker Designed AR 4201 - ( O) (GK 415) Marine Radio User Manual


 
o
Mode 1 (standard mode)
The last displayed active and preset frequencies appear in the LCD dis-
play.
The preset frequency (bottom line) is set using the MHz and kHz fre-
quency selector switches.
When the exchange key is pressed, a change from the active to the pre-
set frequency occurs. A further operation of the key cancels the frequen-
cy change.
Pressing the STO key in any mode initiates a store operation. CH and
the last called up storage channel appear flashing in the bottom line. A
different storage channel can be selected in steps of 1 using the kHz fre-
quency selector. The MHz frequency selector enables storage channels
to be selected in steps of 10. If a free channel is selected, one in which no
frequency has as yet been stored, the letter F (free channel) appears in
the bottom line before CH. The storage operation is ended by again
pressing the STO key, which stores the active frequency displayed in the
top line in the channel shown in the bottom line.
Operating Instructions
Page 16 Issue 05/2000
o
Setting the temperature display in °C or °F
Not activated in the portable VHF station. SF7 is not displayed
o
Switching on the scan function
Call up function SF8 using the MDE key. The following display appears :
Top line SF 8
Bottom line 0 or 1
Select the required function using the kHz switch and store the selection
by pressing the STO key.
0 = scan function off
1 = scan function on
If scan function is not activated, than functions SF9, SF13 and SF14 are
not displayed.
o
Setting the hold time in the scan function (if funtion SF8 acti-
vated)
Call up function SF 9 using MDE key. The following displays appear :
Top line SF 9
Bottom line 0.0 to 60.0
The hold time can be set as required between 0 and 60 seconds using
the kHz switch. The set value is stored by pressing the STO key.
Becker GK 415 - ( )
Issue 05/2000 Page 25