8 Installation - Subtended Network 78-5481-02 09/15/98
Cisco 6100 Set Up and Installation Manual8-8
Using either the ferrite beads shipped with the DS3 NI module (type 43) or ones that use ferrite
material type 43 or 44 with an impedance of >200 ohms +/- 20% at 100 MHz, attach the beads close
to the transmit and receive BNC connectors on the DS3 subtend card. See Figure 8-2 for the location
of the BNC connectors.
If you are using thick type 734A coaxial cable, run the cable through the ferrite bead and clamp it
shut, as shown in Figure 8-6.
Figure 8-6 Thick Coaxial Cable through Ferrite Bead
If you are using thin type 735A coaxial cable, run the cable through once, then loop it back through
the ferrite bead and clamp it shut, as shown in Figure 8-7.
Figure 8-7 Thin Coaxial Cable through Ferrite Bead
Thick coaxial
cable
Ferrite
bead