Eagle Electronics 500C, 500CDF Fish Finder User Manual


 
55
To adjust and turn on the shallow alarm:
1. Press MENU|MENU| to ALARMS|ENT| to SONAR ALARMS|ENT.
2. Press to
SHALLOW ALARM DEPTH|ENT.
3. Press or to change the first number, then press to move the
cursor to the next number and repeat until the depth is correct, then
press
ENT.
4. Press to
SHALLOW ALARM ENABLED|ENT|EXIT|EXIT|EXIT.
5. To turn off the alarm, press
MENU|MENU| to ALARMS|ENT| to
SONAR ALARMS|ENT|ENT|EXIT|EXIT|EXIT.
To switch to a different depth setting, open the Sonar Alarms menu and
repeat the instructions in step 3 above.
To adjust and turn on the deep alarm:
1. Press MENU|MENU| to ALARMS|ENT| to SONAR ALARMS|ENT.
2. Press to
DEEP ALARM ENABLED| to DEEP ALARM DEPTH|ENT.
3. Press or to change the first number, then press to move the
cursor to the next number and repeat until the depth is correct, then
press
ENT.
4. Press to
DEEP ALARM ENABLED|ENT|EXIT|EXIT|EXIT.
5. To turn off the alarm, press
MENU|MENU| to ALARMS|ENT| to
SONAR ALARMS|ENT| to DEEP ALARM ENABLED|ENT|EXIT|EXIT|EXIT.
To switch to a different depth setting, open the Sonar Alarms menu and
repeat the instructions in step 3 above.
Zone Alarm
The zone alarm is triggered when any echo passes inside the zone
alarm bar, shown on the right side of the screen.
To adjust and turn on the zone alarm:
1. Press MENU|MENU| to ALARMS|ENT| to SONAR ALARMS|ENT.
2. Press to
ZONE ALARM ENABLED| to ADJUST ZONE|ENT.