Edelweiss EQ1-DYN Marine Radio User Manual


 
OPERATING INSTRUCTIONS FOR GAMBIT EQUALIZER EQ1-DYN TECHNICAL DATA
Daniel Weiss Engineering Ltd., Florastr. 42, CH-8610 Uster Page 25 of 27
) +41 1 940 20 06 2 +41 1 940 22 14 8 http://www.weiss.ch * weiss@weiss.ch
Dump Remote Control
All System-Exklusive commands consist of a header, a message type, possible data and the EOS (end of
system exclusive). Below is the format of the header:
Byte Value Description Section
1
F0
Sysex
Header
2
00
Manufacturer's ID
3
30
Manufacturer's ID
4
5A
Manufacturer's ID
5
07
Model ID: 6 = Gambit EQ DYN
6
0000nnnn
Device ID: -> Midi channel number
Following is a list of the supported MIDI system exclusive commands (without header):
Snapshot format for dump. A complete dump consists of 128 snapshots:
Byte Value Description Section
1-6
...
...
Header
7
00000001
message = Snapshot dump
Message Type
8
0nnnnnnn
Package number ( 0..7F)
Data
9
0nnnnnnn
scale set number
10 - 265
0nnnnnnn
256 Bytes of Snapshot data
266
0ccccccc
Checksum without byte one (F0 Sysex Command)
Checksum
267
F7
EOS
EOS
Dump request:
Byte Value Description Section
1-6
...
...
Header
7
00000010
message = dump request
Message Type
8
F7
EOS
EOS
Version request:
Byte Value Description Section
1-6
...
...
Header
7
00000011
message = version request
Message Type
8
F7
EOS
EOS
Version send:
Byte Value Description Section
1-6
...
...
Header
7
00000100
message = send version
Message Type 4
8
0vvvvvvv
OS Version
data
9
0vvvvvvv
DSP Version