Edelweiss EQ1-DYN Marine Radio User Manual


 
OPERATING INSTRUCTIONS FOR GAMBIT EQUALIZER EQ1-DYN OPERATION
Daniel Weiss Engineering Ltd., Florastr. 42, CH-8610 Uster Page 9 of 27
) +41 1 940 20 06 2 +41 1 940 22 14 8 http://www.weiss.ch * weiss@weiss.ch
Adjusting Band Parameters
To adjust boost, Q/ slope or frequency simply
turn the corresponding knob (see Table 1).
To adjust the mode, activate the band. Press a
key (Table 2) to change the mode value. The ac-
tive mode is highlighted and the adjacent softkey
is lit.
If the band bypass is on (highlighted), its filter
settings (type and parameters) are saved but have
no effect on the audio signal. Turning bypass off
will restore the previous band settings.
Bypassing all bands is sonically equivalent to
using the overall bypass (refer to EQ Bypass)
if the gain is set to 0.0dB.
Only bands 1, 2, 5, and 6 can be set into dynamic
mode. This allows for linear gain adjustment be-
fore and after a dynamic band.
Controls
See Graph 1: Front Panel Elements, Ž.
CH1 & CH2
These two keys patch the band controls to the
according channels. The band controls can either
be separate for each channel or ganged together.
The key is lit for the active channel.
To copy CH1 settings to CH2 or vice versa, press
the “copy” key and select an option (Graph 6).
Ganged
When this key is lit, the band controls act for both
channels simultaneously. Switching channels while
the “ganged” key is lit will activate CH1 and CH2
settings alternately for both channels.
If ganged is off, the controls will affect the active
channel only.
“boost” “Q/ slope” “frequency”
Peaking-Filter
set boost set Q set centre frequency
Dynamic-Peaking
set boost set Q / threshold set centre frequency
Shelve-Filter
set boost set shape set 3dB frequency
Cut-Filter
- set slope set -3dB frequency
Table 1
Key A Key B Key C Key D
Mode
toggle lo- / hi-
shelve
toggle peaking
/dynamic peaking
toggle lo- / hi-cut bypass
Table 2