Elinchrom Ranger RX Marine Battery User Manual


 
10
Replacement of fuses for Ranger RX
1. 30 A Auto fuse (on the top side of the Battery Box).
2. 4 AF (Quick acting / 5 x 20 mm) charge fuse (on the top side of the Battery Box)
3. 10 AF (Quick acting / 5 x 20 mm) modelling lamp fuse inside Ranger RX housing.
The Battery Box must be removed before the fuse can be exchanged.
4. An additional modelling lamp fuse is in every Free Lite ashhead!
Standard type 5 x 20 mm, 10 AF (quick-action).
For exchanging a blown fuse: Depress and turn the fuse
holder anti-clockwise 1/8th and remove it. If the new fuse
blows immediately upon reconnection return the pack to an
ELINCHROM service centre for a check-up.
(Check correct value of the fuse: 10AF).
Fuse 10AF
Code: 19038
Charge fuse 4 AF
Battery Box:
Code: 19290
Auto fuse 30 A
Code: 19035
Code: 19000
Ranger RX Sockets (16, 17)
To connect ashheads, switch off the unit.
Remove the security cover.
Insert the ashhead plug into the ash socket 16, or 17, (the plug ts
only in one position) and turn the bayonet locking ring clockwise!
The unused socket must be closed with the security cover.
16
The 12 V/ 7Ah Gel Electrolyte Battery can be recharged from any charge level, there is no Memory-Effect.
The number of ashes may vary from Battery to Battery (due to aging, recycling speed etc.)
Even new Batteries may vary, the full capacity of the Battery is available only after some charge cycles.
Used batteries may need to be recycled Check your local regulations!
Use only the original batteries from Elinchrom.
19293
Note:
17
• Always switch off the unit before connecting or disconnecting ashheads!
• The head connector must always be locked with the bayonet before any use.
!
Use only the Elinchrom Rapid Charger Code 19283. Any alternative charger may damage the unit!!
The EL Rapid Charger is universal voltage. To charge the battery while it is inside the unit, connect
the charger to socket 15.
The charger has a coloured LED indicating:
Red: the unit is charging (approx. 3 hrs min. to full).
Green: charging is completed (but if not disconnected no damage will occur,
the charge rate stabilizes almost at zero).
Yellow: will indicate if the battery is over discharged or if a battery has been
incorrectly replaced in the Battery Box (reversing polarity).
The Ranger RX battery can be recharged whilst the unit is in use !
Battery Charging / Fuses