Emerson 1066 Marine Instruments User Manual


 
Specifications
GENERAL SPECIFICATIONS
Case: Polycarbonate. IP66 (CSA, FM), NEMA 4X (CSA)
Dimensions: Overall 155 x 155 x 131mm (6.10 x 6.10 x 5.15 in.). Cutout: 1/2 DIN 139mm x 139mm (5.45 x 5.45 in.)
Conduit openings: Six. Accepts PG13.5 or 1/2 in. conduit fittings
Display: Monochromatic graphic liquid crystal display. No backlight. 128 x 96 pixel display resolution. Active display
area: 58 x 78mm (2.3 x 3.0 in.). All fields of the main instrument display can be customized to meet user requirements.
Ambient temperature and humidity: -20 to 65°C (-4 to 149°F), RH 5 to 95% (non-condensing).
Storage Temperature: -20 to 70°C (-4 to 158°F)
HART
®
Communications: PV, SV, TV, and 4V assignable to measurement, temperature and all live HART diagnostics.
RFI/EMI: EN-61326
Complies with the following Standards:
CSA: C22.2 No 0 – 10; C22.2 No 0.4 – 04; C22.2 No. 25-M1966: , C22.2 No. 94-M91: , C22.2 No.142-M1987: , C22.2
No. 157-M1992: , C22.2 No. 213-M1987: , C22.2 No. 60529:05. UL: 50; 508; 913; 1203. ANSI/ISA: 12.12.02-2011.
ATEX: IEC 60079-0:2011, 60079-11:2011
IECEx: IEC 60079-0: 2011 Edition: 6.0, I EC 60079-11 : 2011-06 Edition: 6.0
FM: 3600: 2011, 3610: 2010, 3611: 2004, 3810: 2005, IEC 60529:2004, ANSI/ISA 60079-0: 2009, ANSI/ISA 60079-11: 2009
Hazardous Location Approvals
Intrinsic Safety (with appropriate safety barrier):
Class I, II, III, Div. 1
Groups A-G
T4 Tamb = -20°C to 65°C
1180 II 1 G
Baseefa04ATEX0195X
EEx ia IIC
T4 Tamb = -20°C to 65°C
Non-Incendive:
Class I, Div. 2, Groups A-D
Dust Ignition Proof
Class II & III, Div. 1, Groups E-G
NEMA 4/4X, IP66 Enclosure
T4 Tamb = -20°C to 65°C
3
Instruction Sheet 1066
LIQ_MAN_ABR_1066-CT-HT-FF-FI July 2013
ATEX
IECEx BAS 11.90098X
EEx ia IIC
T4 Tamb = -20°C to 65°C
Class I, II & III, Division 1, Groups A-G T4
Tamb = -20°C to 40°C for -FI option
Tamb = -20°C to 65°C for -HT and -FF options
Class I, Zone 0, AEx ia IIC T4
Tamb = -20°C to 40°C for -FI option
Tamb = -20°C to 65°C for -HT and -FF options
Class I, Division 2 Groups A-D
Dust Ignition proof
Class II & III, Division 1, Groups E-G
IP66 enclosure
Tamb = -20°C to 40°C for -FI option
Tamb = -20°C to 65°C for -HT and –FF options