Furuno 2837SW Marine RADAR User Manual


 
2. WIRING
2-15
For FAR-2837SW
Fabricating of RW-9600
1. Fabricate the signal cable
RW-9600 as shown right.
2. Unravel the shield to expose
the wires in the inner layer.
3. Shorten each core considering
its location on the terminal
board.
4. Trim each wire (except coaxial
wire) considering its location on
the terminal board.
5. Trim the shield leaving 30 mm
and fold back it.
6. Remove insulation of each wire
by about 6 mm.
7. Insert each wire into the
connector using the terminal
opener.
8. Connect the coaxial wire to
TB802 on the TB Board, and
then fix its shield to the cable clamp.
Wiring for Coaxial cable
CAUTION
Clamp shied with bracket.
Tighten conductor with screw.
Procedures
1. Twist the conductor.
2. Press the terminal opener downward.
3. Insert the wire to hole.
4. Remove the terminal opener.
5. Pull the wire to confirm that it is ecure.
Terminal opener
Wiring for WAGO connector
WAGO connector
Wire
Twist
Press downward.
Do not use crimp-on lug to prevent
contact resistance from increasing.
Shield
Fold back shield.
Conductor
6
14
5
9
Coaxial cable
Approx. 250
5
30
Unit: mm
Vinyl sheath
Armor
Shield
Fold back the shield.
(30 mm)