Furuno FA-150 Marine RADAR User Manual


 
14
*: Waterproofing connectors
Wrap connector with vulcanizing tape and then vinyl tape. Bind the tape end with
a cable-tie.
Waterproofing connector
**: DPYC-2.5, TTYCS-1Q and TTYCS-4 are Japan Industry Standard cables.
Use them or the equivalents, referring to the Appendix.
Cable connection at transponder
Fabrication of cables TTYCS-4, TTYCS-1Q and TTYCS-1
L
6
Remove paint
by 50 mm.
Vinyl tape
Shield
45
50
Cut vinyl sheath.
Expose core and fold back
shield onto cable.
Lay in clamp
where paint
was removed.
L: Depends on equipment connected.
Measure at the transponder.