Furuno FCV-582L SONAR User Manual


 
SP - 2
3. I/O DATA
(1) Input Data NMEA0183(Ver.1.5/2.0), current loop
RMA: L/L, ground track speed, advance course
RMB: Waypoint bearing/distance, cross track error
RMC: L/L(GPS), ground track speed, advance course
BWC: Waypoint bearing/distance
BWR: Waypoint bearing/distance
GLL: L/L
VTG: Ground track speed, advance course
VHW: Water track speed, advance course
MTW: Water temperature
XTE: Cross track error
(2) Output Data NMEA0183(Ver.1.5/2.0), RS-422, output period: 2 sec.
SDDBT(Ver1.5): Depth (ft, m, fa)
SDDPT(Ver2.0): Depth (m)
YCMTW*: Water temperature
VWVHW*: Water track speed
*: Speed/temperature sensor is required.
4. POWER SUPPLY
(1) Voltage and Current 12 - 24 VDC: 1.5 - 0.5 A
5. DIMENSIONS AND MASS
See Outline Drawing
6. ENVIRONMENTAL CONDITION
(1) Temperature -15 °C to +55 °C
(2) Relative Humidity 95% or less at 40 °C
(3) Waterproofing IEC IPX5
(4) Category of Equipment Units
Display Unit: To be installed in a protected area
7. COATING COLOR
(1) Display Unit Panel: N3.0 Newtone No.5
Chassis: 2.5GY5/1.5