Furuno FI-504 Fish Finder User Manual


 
1. OPERATION
7
Environment category
Autopilot category
Engine category
Note: In case of multiple engines, the data of desired engine number
(max. eight, E0-E7) can be selected with the SELECT/CLEAR key.
Display title Indication Function
Battery voltage VOLTS Battery voltage.
Minimum battery voltage
alarm
VOLTS LO
Set low battery voltage alarm.
Audio and visual alarms are
released when the battery
voltage goes lower than the
threshold value.
Time - Current time, in 12-hour or
24-hour format.
Date - Current date.
Water temperature WATER Water temperature, in
°C or °F.
Air temperature AIR
° Air temperature, in °C or °F.
Air pressure HPA Air pressure, in Hectopascal.
Humidity HUMID Relative humidity, in percentage.
Wind chill temperature CHILL Wind chill temperature, in
°C or
°F.
Dew point DEW Dew point, in
°C or °F.
Display title Indication Function
Rudder angle
RUDDER Rudder angle, in degrees either
P(ort) or S(tarboard).
Display title Indication Function
Trip fuel used
TOTAL Total fuel consumption, in liters
or gallons.
Fuel rate
RTE (L/H) Amount of fuel consumed in
hour, in liters/hour (L/H) or
gallons/hour (G/H).
Engine RPM
RPM Engine speed per minute.
Display scrolling speed and direction can be changed by the length of
key push.
Short push: Scroll in forward order.
Medium push: Go back one display. Several beeps sound and then the
previous display appears.
Hold down: Rapid scrolling, in forward direction. Several beeps sound
and then speed is changed.
Scrolling speed and scrolling direction