Furuno FI-504 Fish Finder User Manual


 
3. INSTALLATION
24
Set speed response. The lower the
setting the faster the response to
change in speed.
0 - 12 0
Set SOG response. The lower the
setting the faster the response to
change in speed over ground.
0 - 12 0
Set VMG response. The lower the
setting the faster the response to
change in velocity made good.
0 - 12 3
Enable/disable the timer alarm’s
audio alarm.
ON, OFF ON
Select source of wind data. Select
“r” for second unit.
F: For FI-5001,
r: repeater
F
Select wind unit. KT (Knot),
M/S (Meters/Second)
KT
Set wind speed
adjustment.
0.3 - 2.5 1.0
Set wind angle offset. S 0
° - 180°
P 1° - 179°
0
Set wind speed response.
The higher the setting the faster
the response to change in wind
speed.
0 - 12 3
Setup1 menu items
Display Function
Setting range or
options
Default
setting
SPD RES
CAL
0
0
SOG RE
S
CAL
0
VMG RES
CAL
3
3
TIMER
CAL
O
n
n
WIND
CAL
F
F
WIND KT
CAL
WINDADJ
CAL
1
.0
ANGLE S
CAL
0
WSPDRES
CAL
3