Furuno FR-8045 Marine RADAR User Manual


 
3. ARPA OPERATION
3-7
3.8 ARPA Target Data
You can show the data for a tracked ARPA target in the data box at the bottom of the
screen. To display ARPA target data, the menu item [Display] on the [ARPA] menu
must be set for [On] and the menu item [Data Box] on the [Display] menu must be set
for [Target] or [All].
1. Use the CursorPad to put the cursor on an ARPA target.
2. Press the ENTER key to show the data of the target.
ARPA target data
The symbol for the selected ARPA target is enlarged double to identify it from other
symbols.
To remove the data of a target from a data box, put the cursor on its target symbol and
press the CANCEL/HL OFF key.
Vector reference
Vector time
Target no.
Bearing, range, course,
speed,CPA, TCPA
+
ARPA target
selected for
data display
(B)01
Data box
Cursor
TRUE 06:00<ARPA> No. 02
A
BRG 78.4ºT RNG 2.032NM
SOG 0.49KNCRS 73.0º
TRUE 06:00<ARPA> No. 01
B
BRG 29.3ºT RNG 0.659NM
SOG 0.10KNCRS 12.3º
(A)02