2.3.3 How to connect cables to the monitor unit
Connect the monitor cable and control cable to the monitor (FURUNO-supplied
monitor) unit as below.
1. Unfasten four screws (M4x10) at the rear of the monitor to loosen the cable
cover.
2. Lift and pull the cable cover to remove it.
3. Unfasten two screws (M4x10) to remove the clamp cover.
4. Lay the monitor and control cables on the clamp, and then reattach the
clamp plate to fix cables.
5. Connect eight connectors referring to the instruction sticker by the connector
board.
6. Reattach the cable cover.
Cable cover
Monitor cable
Control cable
Clamp
Connector board
CN-A306
CN-A305 CN-A304
3
45
21
CN-A308 CN-A307
CN-A301
CN-A303
CN-A302
CONTROL UNIT
PROCESSOR
UNIT
PROCESSOR UNIT
B
G
R
H
V