10. Place meter in a vise as shown in FIG. 38. Use new
trip rod from your kit (2) or a non-metal rod or dowel
to push trip rod through meter housing (F
IG. 38 and
F
IG. 39) far enough to access pin (19) holding
together trip rod and trigger.
11. Use a pick to push pin (19) out (F
IG. 39).
12. Remove trigger assembly (6) from meter housing.
13. Remove trip rod assembly from meter housing.
Cleaning Trip Rod
a. If the trigger does not reset sufficiently to dis-
pense fluid, clean trip rod and spring with a soft
brush and cleaning fluid such as mineral spirits.
b. Inspect trip rod and spring. If damaged, replace
using Trip Rod Replacement Kit 255889.
F
IG. 38
F
IG. 39
F
IG. 40
ti12011a
19
19
ti12012a
ti12016a
6
Be careful when you remove the trip rod assembly.
Cover the balls with your fingers or a rag to prevent
them from falling out.
F
IG. 41
ti12013a
6