Setup Mode Screens
16 312865R
Calibrate Screen (FIG. 14)
For All Meters
Recalibrates the meter for different fluids.
Table 1. Calibration Factors
Calibration factors at 70°F (21°C) at 2.0 gpm (7.6 lpm).
Calibration number may vary slightly due to temperature
or flow rate.
All meters include D - M
D. Wrench Icon: Returns user to Main Screen.
J. Calibration Factor: Displays amount operator
dispensed during meter calibration.
K. Preset Calibration Factor: Preset calibration
amount displays.
Adjusting the Preset Calibration Factor:
1. Use your LEFT or RIGHT ARROW to move the
curser to the Calibration Factor Field (K) .
2. Use the UP or DOWN ARROW to manually adjust
the Preset Calibration Factor up or down (this can
only be done on Calibrate Screen 1 (F
IG. 14).
3. Press center, ENTER button to confirm new setting.
New setting displays in Calibration Factor field (J).
L. Start/End button: Clicked at the start and completion
of calibration. See Recalibrating the Meter (page 17).
M. Dispense: Only appears on Screen 2 (F
IG. 14).
Displays amount operator dispensed during calibration
test.
Fluids
Calibration Number
Quarts Liters
Oil (10W - 30)
173 183
Gear Lube
173 183
Automatic
Transmission Fluid
167 176
Antifreeze
159 168
F
IG. 14
D
J
M
K
L
L
Calibrate Screen 1
Calibrate Screen 2
ti12173a