17
“B” Group: Fine-tuning Functions
A_82 AVR voltage select 230/230/200
400/460/400
A_92 Acceleration (2) time setting 15.0
A_93 Deceleration (2) time setting 15.0
A_94 Select method to switch to Acc2/Dec2
profile
• 002CH input from terminal
• 01transition frequency
00
A_95 Acc1 to Acc2 frequency transition point 0.0
A_96 Dec1 to Dec2 frequency transition point 0.0
A_97 Acceleration curve selection
• 00Linear • 01S-curve
00
A_98 Deceleration curve selection
• 00Linear • 01S-curve
00
Func.
Code
Name / Description
Default
Value
–FE / –FU /
–FR
Set
Value
B_01 Selection of automatic restart mode
• 00Alarm output after trip, automatic
restart disabled
• 01Restart at 0Hz
• 02Resume operation after frequency
matching
• 03Resume previous freq. after freq.
matching, then decelerate to stop and
display trip info
00
B_02 Allowable under-voltage power failure
time
1.0
B_03 Retry wait time before motor restart 1.0
Func.
Code
Name / Description
Default
Value
–FE / –FU /
–FR
Set
Value