12
OPTIONAL INSTALLATIONS
■ UT-102
VOICE SYNTHESIZER UNIT
The UT-102 announces the accessed frequency in a
clear, electronically generated voice, in English (or
Japanese) when pushing [SPCH] or when a signal is
detected during scan (see p. 31, 32 for settings).
➀Remove the top cover as shown opposite.
➁Remove the protected paper attached to the bot-
tom of the UT-102 to expose the adhesive strip.
➂Connect the UT-102 as shown in the diagram at
right.
➃Replace the top cover.
J12
UT-102
■ FL-52A
CW NARROW FILTER
The IC-R8500 has a CW narrow mode which pro-
vides better S/N (signal-to-noise) and also rejects
nearby interference. The CW narrow filter is helpful
when receiving CW and radio-teletype signals.
➀Remove the top cover as shown opposite.
➁Connect the FL-52A as shown in the diagram at
right.
•Make sure it is connected in the proper orientation.
•Attached nuts on the FL-52A are not necessary. If you
want to install the filter more securely, open the MAIN
unit, then use the nuts on the bottom of the MAIN unit.
➂Replace the top cover.
FL-52A
Under the top cover
Under the top cover