Index Interfurn 90-823226 Marine Sanitation System User Manual


 
POWER STEERING - 8A-1790-823226--1 996
Filling System with Fluid
1. Fill pump reservoirs with automatic transmission
fluid (ATF) Dexron ll or Dexron lll.
2. Install and tighten pump cap by turning cap clock-
wise approximately 120 degrees.
72868
a
a - Cap
3. Fill reservoir bottle to full mark, then (one at a
time) slightly loosen pump cap to allow fluid to
flow from reservoir to pump until pump just starts
to overflow, then quickly tighten pump cap. Fill
bottle reservoir and repeat this process for the
other pump.
4. Double check both caps to ensure they are both
tight.
Maintenance
Maintenance inspection is the owner’s responsibility
and must be performed at the following intervals:
Normal Service - Every 50 hrs. of operation or
60 days (whichever comes
first)
Severe Service - Every 25 hrs. of operation or
30 days (whichever comes
first)
NOTE: Operation in salt water is considered se-
vere service.
1. Check all connections and hose clamps for ade-
quate tightness. Tighten, if loose.
2. Check all mounting bolts and tighten if necessary.
3. Be sure to check reservoir oil level periodically.
Index