6
1 INSTALLATION
PANEL AND MICROPHONE CONNECTION
Plug the microphone plug to the MIC jack (8-wire/ RJ45), then connect the Remote Control panel to the TX/ RX
unit with the supplied cable (2 m/ 6-wire/ RJ11).
PADDLE
KEY
EXT.SP DATA REMOTE
COM
MIC
PANEL
Microphone
To PANEL
To MIC
3cm
Line filter
PANEL AND MICROPHONE CONNECTION USING PG-4Z (OPTION)
Use the cables and connectors to connect the Remote Control panel and TX/ RX unit with the PG-4Z cable kit as
shown below.
PADDLE
KEY
EXT.SP
DATA REMOTE
COM
MIC
PANEL
To MIC
To EXT.SP
To external speaker
External speaker extension
cable from the PG-4Z cable
kit (when the external speaker
is used)
Extension adaptor (RJ11)
from the PG-4Z cable kit
Extension cable (RJ11)
from the PG-4Z cable kit
Extension adaptor (RJ45)
from the PG-4Z cable kit
Line filter (large) from
the PG-4Z cable kit
Extension cable (RJ45)
from the PG-4Z cable kit
Line filter (small) from
the TS-480
3 cm
3 cm
EXT.SP DATA
REMOTE
PANEL
1 cm
Line filter (small) from
the PG-4Z cable kit
Tapping screw
(4 mm x 14 mm)
Flat washer
Microphone cable
Double-sided
adhesive tape
RJ45 (8-wire)
adaptor
Cable
holder