Multiquip BA SONAR User Manual


 
PAGE 22 — BA-SERIES WALK-BEHIND TROWEL— OPERATION & PARTS MANUAL — REV. #2 (03/19/04)
BA-SERIES TROWEL— PRE-INSPECTION
It is recommended that the trowel's
Engine-Off Safety Switch
be used to stop the engine after every use. Doing this will verify
that the switch is working properly and presents no danger to the
operator.
Before Starting
1. Read safety instructions at the beginning of manual.
2. Clean the
trowel
, removing dirt and dust, particularly the
engine cooling air inlet, carburetor and air cleaner.
3. Check the air filter for dirt and dust. If air filter is dirty, replace
air filter with a new one as required.
4. Check carburetor for external dirt and dust. Clean with dry
compressed air.
5. Check fastening nuts and bolts for tightness.
Engine Oil Check
1. To check the engine oil level, place the trowel on secure level
ground with the engine stopped.
2. Remove the filler dipstick from the engine oil filler hole
(Figure 17) and wipe it clean.
Figure 17. Engine Oil Dipstick (Removal)
3. Insert and remove the dipstick without screwing it into the filler
neck. Check the oil level shown on the dipstick.
4. If the oil level is low (Figure 18), fill to the edge of the oil filler
hole with the recommended oil type (Table 4). Maximum oil
capacity is 400 cc.
Figure 18. Engine Oil Dipstick (Oil Level)
epyTliO.4elbaT
nosaeS erutarepmeT epyTliO
remmuS rehgiHroC°52 03-W01EAS
llaF/gnirpS C°01~C°52 02/03-W01EAS
retniW rewoLroC°0 01-W01EAS
DANGERDANGER
DANGERDANGER
DANGER
NEVER operate the trowel in a confined
area or enclosed area structure that does
not provide ample
free flow of air
.
NOTE
Reference manufacturer engine
manual for specific servicing
instructions.
ALWAYS wear approved eye and hearing
protection before operating the trowel.
NEVER place hands or feet inside the guard
rings while the engine is running. ALWAYS
shut the engine down before performing any
kind of maintenance service on the trowel.
CAUTIONCAUTION
CAUTIONCAUTION
CAUTION