Component Inspection Instructions
1) Examine the single point status indicator through the window panel
(Fig. 1). Ensure the indicator is green. If the indicator is red, the
mechanism has been fired or is incorrectly fitted (see Re-arming Your
PFD, p. 9).
NOTE: The single point status indicator must be green before
proceeding.
2) Undo the zipper on the wearer's left side, exposing the oral inflator.
3) Ensure the oral-inflation dust cap is in the stowed position (Fig. 6).
4) Ensure the single point status indicator is green and the pull-
tab lanyard is hanging on the outside; secure the zippers on the
Inflatable PFD (see Repacking, p.13).
5) Ensure the current date is not past the date on the inflator. If it is,
replace the inflator (see Re-arming Your PFD, p. 9).
Readiness Checklist
Check your Inflatable PFD and ensure all of the checkpoints listed below
are true before use.
■ Single point status indicator is green (Fig. 1 and 2).
■ Ensure the current date is not past the date on the inflator. If it is,
replace the inflator (see Re-arming Your PFD, p. 9).
■ All zippers, Velcro
™
and waist buckle are securely fastened.
■ Oral-inflation dust cap is in the stowed position (Fig. 7).
■ Inflatable PFD is not twisted.
■ Ensure the inflation pull-tab is hanging on the outside (Fig. 30).
■ No rips, tears, excessive abrasion or holes; all seams are securely
sewn; and the cover, straps and hardware are still strong.
Your Inflatable PFD is ready for use if all applicable boxes are checked.
NOTE: Contact your Mustang Dealer if you have any concerns
4 Inflatable PFD Owner’s Manual Inflatable PFD Owner’s Manual 5