Oceanic 04.8367.16 Scuba Diving Equipment User Manual


 
22
ATOM 3.0 OPERATING MANUAL
© 2002 Design, 2011 Doc. No. 12-5216-r02 (9/6/11)
Set SS (NORM Safety Stop), information includes (Fig. 62):
> Graphics SEt and SAFE St with Stop arrow/bar icons.
> Set Point graphic ON (or OFF) flashing.
- or -
> Graphic SEt with Stop arrow/bar icons.
> Set Point graphic ON TMR flashing.
• A (< 2 sec) - to step forward through the Set Points (SAFE St OFF, SAFE St ON, TMR ON).
• S (< 2 sec) - to save the setting.
• S (2 sec), if no change - to revert to Set DS.
>> If SS OFF (Fig. 60A, page 58) or TMR ON (Fig. 60B) is selected, operation accesses Set Algorithm.
>> If SS ON is selected, Stop Depth and Time is displayed with min and sec icons, Time digits flashing (Fig. 60C).
• A or M (< 2 sec) - to toggle Stop Time Set Points between 3:00 and 5:00 (min:sec).
• S (< 2 sec) - to save the Time setting and flash Depth digits.
• A (< 2 sec) - to step up through Depth Set Points of 10, 15, and 20 FT (or 3, 4, 5, and 6 M).
• M (< 2 sec) - to step back through Set Points.
• S (< 2 sec) - to save the setting and access Set Algorithm.
Set Algorithm (NORM), information includes (Fig. 63):
> Graphics SEt and ALGO.
> Set Point graphic PZ+ (or DSAT) flashing.
• A or M (< 2 sec) - to toggle between DSAT and PZ+.
• S (< 2 sec) - to save the setting and access Set CF.
• S (2 sec), if no change - to revert to Set SS.
This feature allows selection of the Algorithm to be used for nitrogen and oxygen calculations for Plan and Dive allowed time values.
The setting locks in for 24 hours after NORM dives.
Set CF (Conservative Factor, NORM), information includes (Fig. 64):
> Graphics SEt and CF with icon.
> Set Point graphic ON (or OFF) flashing.
• A or M (< 2 sec) - to toggle between ON and OFF.
• S (< 2 sec) - to save the setting and access Set Glo.
• S (2 sec), if no change - to revert to Set Algorithm.
When CF is set On, NDLs are reduced to values equivalent to those that would be available at the next higher 3000 foot (915 meter) Altitude.
Refer to tables in back of manual.
Set Glo (Backlight Duration), information includes (Fig. 65):
> Graphics SEt and GLO.
> Time Set Point value flashing with sec icon.
• A (< 2 sec) - to step upward through Set Points of 0, 5, and 10 (sec) one at a time.
• M (< 2 sec) - to step back through Set Points one at a time.
• S (< 2 sec) - to save the setting and access Set SR.
• S (2 sec), if no change - to revert to Set CF.
Backlight Duration is the time the backlight will remain On after the L button is released (0 = no additional time).
Set SR (Sampling Rate), information includes (Fig. 66):
> Graphics SEt and SR.
> Time Set Point value flashing with sec icon.
• A (< 2 sec) - to step upward through Set Points of 2, 15, 30, and 60 (sec) one at a time.
• M (< 2 sec) - to step back through Set Points one at a time.
• S (< 2 sec) - to save the setting and access Set TMT 1.
• S (2 sec), if no change - to revert to Set Glo.
Sampling Rate is the frequency at which data is sampled and stored for download to the OceanLog PC Interface program.
A
Fig. 62 - SET SS
B
C
Fig. 63 - SET ALGORITHM
Fig. 64 - SET CF
Fig. 65 - SET GLO
Fig. 66 - SET SR