Oceanic 04-8792-49 Scuba Diving Equipment User Manual


 
17
OCi OPERATING MANUAL
© 2002 Design, 2013 Doc. No. 12-5335-r01 (6/27/13)
NORM SURFACE FUNCTIONS
L

S
2 sec
A
< 2 sec






















S
< 2 sec


M
2 sec


M
< 2 sec
A
< 2 sec
M
< 2 sec
M or S
2 sec
DIVE COMPUTER OPERATING MODES
NORM Mode >> for Air and Nitrox SCUBA activity with up to 4 Gases and 4 Transmitters.
GAUG Mode >> for SCUBA activity with Depth/Time indication and up to 4 Transmitters.
FREE Mode >> for general breath hold diving activities with Depth/Time indication.
TECH FREE Mode >> for very deep breath hold diving activities with Depth/Time indication.
If no previous dive has been taken within the past 24 hours, NORM is the default upon access from Watch Time. Others operating modes can be accessed
from the Main Menu.
At any time while operating in Surface Modes, operation will enter the Scuba dive mode selected (NORM or GAUG) upon descent to 5 FT (1.5 M) for 5
seconds, or the FREE dive mode selected upon descent to the DSD (Dive Start Depth) set for 5 seconds.
• When Wet Activation is set Off, dive mode will only activate when operating in a Dive Computer mode. It will not activate while in Watch Mode
unless it is a repetitive dive in a series.
• When Wet Activation is set On, the selected dive mode will activate upon descent regardless of what mode it is operating in at the time.
Post Dive:
Operation will revert from Dive Mode to Post Dive Surface Mode upon ascent to 2 FT (0.6 M) for 1 second.
During the Transision Period, which is the first 10 minutes on the surface after a NORM or GAUG dive, or after the BDSI (Between Dive Surface Interval)
time set after a FREE or TECH FREE dive >>
• The Surface Main will be displayed with Surface Interval time and access to Surface ALT screens.
• A descent during the Transition Period is a continuation of that dive.
After the 10 minute (or BDSI) interval on the surface has elapsed >>
• The Surface Main will be displayed with access given to other surface displays.
• A descent is then considered a new dive.
----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
S 2 sec while viewing
the Menu to revert to
SURF Main.
S
< 2 sec
S
2 sec
(sample selection)