Oceanic 04-8792-49 Scuba Diving Equipment User Manual


 
9
OCi OPERATING MANUAL
© 2002 Design, 2013 Doc. No. 12-5335-r01 (6/27/13)
PC (PERSONAL COMPUTER) INTERFACE
Interface with a PC (including Apple), to allow uploading settings and downloading data, is accomplished by connecting the OCi to a PC USB port using
the special Oceanic USB interface cable.
The software program together with the USB driver required is on the Oceanic Product CD, or it can be downloaded from the Oceanic web site. The
program's Help serves as the user manual which can be printed for personal use.
The settings upload portion of the computer interface program can be used to set/change the Watch, Scuba, and Free mode selections using the same
interface system.
Information available for retrieval (download) from the OCi to the download portion of the program includes items such as dive number, surface interval
time, start/end depths, max depth, elapsed dive time, start date/time, lowest temperature, sampling rate, dive profile, and set points.
The computer interface program also allows update of select versions of the OCi's firmware (operating system software).
Refer to page 26 for more details relating to the computer interface system.
AUDIBLE ALARM
While operating in NORM or GAUG Mode the Audible will emit 1 beep per second for 10 seconds when alarms strike, unless it is set Off. During that
time, the Audible can be silenced by pressing the S button momentarily (less than 2 seconds).
An LED Warning Light, on the side of the housing, is synchronized with the Audible and flashes as the Audible sounds. It will turn off when the Alarm is
silenced. The Audible and LED will not be active if the Audible is Set OFF (a Set Alarms setting).
FREE Dive Modes have their own Alarms which emit multiple beeps multiple times which cannot be acknowledged or set Off.
Events that emit (10) beeps >> each sound for .500 sec with .500 sec silence between beeps:
• Watch Daily Alarm.
• Watch CDT Alarm.
• NORM, GAUG - ATR Warning & Alarm.
• NORM, GAUG - Turn Pressure Alarm (TMT 1).
• NORM, GAUG - End Pressure Alarm (TMT in use).
• NORM, GAUG - Loss of Link (Dive Mode).
• NORM, GAUG - Ascent Rate too fast.
• NORM, GAUG - Depth Alarm.
• NORM, GAUG - EDT Alarm.
• NORM - DTR Alarm.
• NORM - TLBG Alarm.
• NORM - entry into Deco.
• NORM - Conditional Violation.
• NORM - Delayed Violations 1, 2.
• NORM, GAUG - Delayed Violation 3.
• NORM, GAUG - entry into Violation Gauge Mode.
• NORM - PO2 Warning and Alarm.
• NORM - O2 Warning and Alarm.
• NORM - Gas Switch Alarm.
Events that emit (3) beeps >> each sound for .500 sec with .500 sec silence between beeps:
• NORM, GAUG - Ascent Rate warning.
• FREE - Delayed Violation 3.
Events that emit (3) sets of (3) beeps >> each sound for .500 sec with .250 sec silence between beeps and .500 sec silence between sets:
• FREE, TECH FREE - SRT Alarm.
• FREE, TECH FREE - RDI Alarm.
RDI is not to alarm at the DD or DA alarm depths.
• FREE, TECH FREE - CDT Alarm.
• FREE - TLBG Alarm.
• FREE - Violation, entry into Deco.
Events that emit (3) sets of (3) beeps >> each sound for .125 sec with .125 sec silence between beeps and .250 sec silence between sets:
• FREE - DD1 to DD3 Alarms.
Events that emit (2) beeps >> each sound for 1 sec with .500 sec silence between beeps:
• FREE, TECH FREE - RTI Alarm.
Events that emit (1, 2 or 3)* sets of (1 to 10)* beeps >> each sound for .125 sec with .125 sec silence between beeps and .250 sec silence between sets:
• TECH FREE - DA1 to DA6 Alarms.
*
Each DA is user adjustable.