Pelco C521M Marine Instruments User Manual


 
6 Pelco Manual C521M (6/95)
4.2.3 Tilt Meter Adjustment
Use the same methods for the tilt adjustment as those
just employed for the pan meter adjustment.
Once the procedure is complete, the extreme electrical
rotation limits can be reset down from the factory maxi-
mum settings.
5.0 OPERATION
When power is applied to the unit the power LED on
the front panel lights.
The pan and tilt meters on the front of the AZL unit
will give a direct, visual, real-time readout, in degrees,
of the physical orientation of the pan/tilt to which it has
been electrically connected.
6.0 SPECIFICATIONS
ELECTRICAL
Input Voltage: 120 VAC, 50/60 Hz
Power Cord: 3-wire grounded #18 Awg
Fuse Protection: F1--3A
F2--2/10ASB
Connectors: 14-pin AMP CPC connector
120 VAC convenience outlet
GENERAL
Construction
Cover: Steel, powder-coated, black
Chassis: Metal sheet, galvanized
Panel
Front: Aluminum, black, white silk screen
Rear: Alodine aluminum plate
Dimensions: 3.0"H x 15.55"W x 10.19"D
(7.62 cm x 39.50 cm x 25.88 cm)
Weight: 12 lbs (5.4 kg)