Raritan Engineering PST*03 Marine Sanitation System User Manual


 
10
WIRING
Flushing Option #1:
"Push to Cycle" button activates both the toilet
and treatment cycle.
Note: Toilet flush time is set at 10 seconds, after
initial 10 seconds holding the button down will
momentarily flush the toilet.
1. Mount Switch Panel near toilet.
CAUTION: Use only the Raritan #CDS (fail-
ure to do so will damage to the Control
Board, voiding warranty).
2. Run 16 ga. wire from terminal H1 on Circuit
Board to one of the small relay terminals.
3. Run a wire from the other small relay terminal
to the Positive supply from battery with a 3 amp
fuse.
Flushing Option #2:
Toilet Push Button -
Flushing toilet will activate treatment cycle.
Note: Toilet may be flushed as often as necessary,
do not exceed recommended flush volume.
1. Mount Switch Panel near toilet.
CAUTION: Use only the Raritan #CDS (failure
to do so will damage to the Control Board,
voiding warranty).
2. Run 16 ga. wire from small relay terminal to S2
on Circuit board and one post of the PBS (push
button switch)
Freshwater, dual installation and manual
toilets:
Solenoid valve supplies water to
tablet dispenser -
1. Mount Switch Panel near toilet.
2. Run 16 ga. wire from battery positive to one of
the wires on the solenoid with 3 amp fuse in line.
3. Run 16 ga. wire from wire on solenoid not used
to H1 on Purasan Circuit Board.
Purasan Circuit Board
on Treatment tank
To toilet
positive (+)
Battery
CDS
TYPICAL INSTALLATION - Flushing Option #1
“Push to Cycle” also activates toilet -
single toilet installation
Small post on
CDS to H1
jumper wire
with
3 amp fuse
TYPICAL INSTALLATION - Flushing Option #2
“Push Button” also activates Purasan -
single toilet installation
PBS
Battery
3 amp
Fuse
Small post on CDS
to S2 and PBS
CDS
To toilet
positive (+)
Purasan Circuit Board
on Treatment tank
TYPICAL INSTALLATION - freshwater, dual
installation and manual toilets
Solenoid required to supply water to tablet
dispenser
Battery