Raritan Engineering PST*03 Marine Sanitation System User Manual


 
3
MAINTENANCE
Use ONLY Purasan Tablets.
DO NOT add any other chemicals or cleaning
products to the toilet or the treatment system.
Raritan C.P. - Cleans Potties and R.C. Raritan
Concentrate are the only factory-recognized cleaning
products that may be used in the toilet.
MAINTENANCE
WARNING: Read and understand all safety
instructions (including Material Safety Data
sheet) for handling Purasan Tablets before
performing any work on the Purasan.
Recommended Visual Inspection
Tablet level in cartridge monthly
Tubes to and from dispenser are unobstructed
Tubes to treatment tank are unobstructed
Replace tablet cartridge only when completely empty.
Clean or replace tubes if any obstruction is found.
REPLACING TABLET CARTRIDGE
(#41-135)
CAUTION: Tablet dispenser may be under pres-
sure. Open lid SLOWLY
Remove used tablet cartridge -
1. With adequate ventilation available - Unscrew
tablet dispenser lid and lift out used tablet car-
tridge.
2. Rinse thoroughly with water to remove any re-
sidual tablet particles.
3. Clean plug assembly
CAUTION: Never dispose of tablets in a dry state
refer to MSDS for proper disposal.
4. Dispose of empty cartridge with other recyclable
plastics.
Loading new tablet cartridge in dispenser
1. Hold new tablet cartridge over tablet dispenser
with large end down. Remove tablet cartridge cap
and allow any loose tablet particles to drop into
the tablet dispenser. Slide tablet cartridge down
into tablet dispenser.
2. Cut nipple off top of tablet cartridge to create
an air hole.
3. Replace lid on tablet dispenser.
CLEANING: Do not add any other chemicals or
cleaning products to the toilet or the treatment system.
INSTALLING TABLET CARTRIDGE